Publication:
Evaluación clínica a tres años de dos sistemas cerámicos en puentes posteriores de cuatro unidades

Loading...
Thumbnail Image
Official URL
Full text at PDC
Publication Date
2012
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Citations
Google Scholar
Research Projects
Organizational Units
Journal Issue
Abstract
Este trabajo de investigación clínica, pretende evaluar de forma prospectiva el comportamiento clínico de restauraciones posteriores a 4 unidades confeccionadas con sistemas cerámicos de óxidos de circonio (IPS e.max , ZirCAD y Lava tm Zirconia). [ABSTRACT]The aim of this investigation is to evaluate on a prospective way the clinical behaviour of post restorations to 4 units which are manufactured with ceramic systems of Zirconium Oxide.
Description
Máster de Ciencias Odontológicas, Facultad de Odontología, Departamento de Estomatología I (Prótesis Bucofacial), 2012
UCM subjects
Unesco subjects
Keywords
Citation
1. Vega J. Porcelanas y cerámicas actuales. RCOE. 1999;4(1):41-54. 2. Vega J. Materiales en odontología: fundamentos biológicos, clínicos, biofísicos y fisicoquímicos. Madrid: Editorial Avances Médico-Dentales; 1996. 3. Probster L. All-ceramic crowns on modified CeraOne abutments: a case report. Quintessence Int. 1998;29(1):52-65. Epub 1998/06/05. 4. McLean JW, Hughes TH. The reinforcement of dental porcelain with ceramic oxides. Br Dent J. 1965;119(6):251-67. Epub 1965/09/21. 5. Suárez M, López J, Salido M, Serrano B. Coronas de recubrimiento total cerámicas. Criterios de selección. Rev Euro Odontoestomatol. 1999(11):249-58. 6. Adair PJ, Grossman DG. The castable ceramic crown. The International journal of periodontics & restorative dentistry. 1984;4(2):32-46. Epub 1984/01/01. 7. Quinn JB, Sundar V, Lloyd IK. Influence of microstructure and chemistry on the fracture toughness of dental ceramics. Dent Mater. 2003;19(7):603-11. Epub 2003/08/07. 8. Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater. 2004;20(5):449-56. Epub 2004/04/15. 9. Martínez Rus F, Pradíes G, Suárez M, Rivera B. Cerámicas dentales: Clasificación y criterios de selección. RCOE. 2007;12(4):253-63. 10. Fons A, Solá M, Martínez-González A, Casa J. Clasificación actual de las cerámicas dentales. RCOE. 2001(6):645-56. 11. Álvarez-Fernández M, Peña-López J, González-González I, Olay-García M. Características generales y propiedades de las cerámicas sin metal. RCOE. 2003(8):252-546. 12. Fons-Font A, Sola-Ruiz MF, Granell-Ruiz M, Labaig-Rueda C, Martinez-Gonzalez A. Choice of ceramic for use in treatments with porcelain laminate veneers. Med Oral Patol Oral Cir Bucal. 2006;11(3):E297-302. Epub 2006/05/02. 13. Zeng K, Oden A, Rowcliffe D. Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains. The International journal of prosthodontics. 1998;11(2):183-9. Epub 1998/08/26. 14. Al-Dohan HM, Yaman P, Dennison JB, Razzoog ME, Lang BR. Shear strength of core-veneer interface in bi-layered ceramics. The Journal of prosthetic dentistry. 2004;91(4):349-55. Epub 2004/04/30. 15. Suarez MJ, Lozano JF, Paz Salido M, Martinez F. Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs. Int J Prosthodont. 2004;17(1):35-8. Epub 2004/03/11. 16. Eschbach S, Wolfart S, Bohlsen F, Kern M. Clinical evaluation of all-ceramic posterior three-unit FDPs made of In-Ceram Zirconia. Int J Prosthodont. 2009;22(5):490-2. Epub 2010/01/26. 17. Bottino MA, Salazar-Marocho SM, Leite FP, Vasquez VC, Valandro LF. Flexural strength of glass-infiltrated zirconia/alumina-based ceramics and feldspathic veneering porcelains. J Prosthodont. 2009;18(5):417-20. Epub 2009/05/13. 18. Pallis K, Griggs JA, Woody RD, Guillen GE, Miller AW. Fracture resistance of three all-ceramic restorative systems for posterior applications. J Prosthet Dent. 2004;91(6):561-9. Epub 2004/06/24. 19. Garvie RC, Hannink RH, T. PR. Ceramic steel? Nature. 1975;258:703-4. 20. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials. 1999;20(1):1-25. Epub 1999/01/23. 21. Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont. 2001;14(3):231-8. Epub 2001/08/04. 22. Kohorst P, Dittmer MP, Borchers L, Stiesch-Scholz M. Influence of cyclic fatigue in water on the load-bearing capacity of dental bridges made of zirconia. Acta Biomater. 2008;4(5):1440-7. Epub 2008/05/27. 23. Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil. 2010;37(8):641-52. Epub 2010/04/22. 24. Sailer I, Pjetursson BE, Zwahlen M, Hammerle CH. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses. Clin Oral Implants Res. 2007;18 Suppl 3:86-96. Epub 2007/06/28. 25. Roediger M, Gersdorff N, Huels A, Rinke S. Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results. Int J Prosthodont. 2010;23(2):141-8. Epub 2010/03/23. 26. Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007;20(4):383-8. Epub 2007/08/19. 27. McLean JW, Kedge MI, Hubbard JR. The bonded alumina crown. 2. Construction using the twin foil technique. Australian dental journal. 1976;21(3):262-8. Epub 1976/06/01. 28. Martínez-Rus F. Estudio experimental del ajuste marginal en coronas cerámicas de alto contenido en circonia [Tesis Doctoral]. Madrid: Universidad Complutense de Madrid; 2005. 29. Vickery RC, Badinelli LA, Waltke RW. The direct fabrication of restorations without foil on a refractory die. J Prosthet Dent. 1969;21(2):227-34. Epub 1969/02/01. 30. Naert I, Van der Donck A, Beckers L. Precision of fit and clinical evaluation of all-ceramic full restorations followed between 0.5 and 5 years. J Oral Rehabil. 2005;32(1):51-7. Epub 2005/01/07. 31. Persson A, Andersson M, Oden A, Sandborgh-Englund G. A three-dimensional evaluation of a laser scanner and a touch-probe scanner. J Prosthet Dent. 2006;95(3):194-200. Epub 2006/03/18. 32. Besimo C, Jeger C, Guggenheim R. Marginal adaptation of titanium frameworks produced by CAD/CAM techniques. Int J Prosthodont. 1997;10(6):541-6. Epub 1998/03/12. 33. Luthardt RG, Sandkuhl O, Herold V, Walter MH. Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations. Int J Prosthodont. 2001;14(2):146-51. Epub 2002/02/15. 34. Beuer F, Edelhoff D, Gernet W, Sorensen JA. Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs). Clin Oral Investig. 2009;13(4):445-51. Epub 2009/01/27. 35. Molin MK, Karlsson SL. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont. 2008;21(3):223-7. Epub 2008/06/14. 36. Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont. 2008;21(3):217-22. Epub 2008/06/14. 37. Vagkopoulou T, Koutayas SO, Koidis P, Strub JR. Zirconia in dentistry: Part 1. Discovering the nature of an upcoming bioceramic. Eur J Esthet Dent. 2009;4(2):130-51. Epub 2009/08/07. 38. Koutayas SO, Vagkopoulou T, Pelekanos S, Koidis P, Strub JR. Zirconia in dentistry: part 2. Evidence-based clinical breakthrough. Eur J Esthet Dent. 2009;4(4):348-80. Epub 2010/01/30. 39. Chong KH, Chai J, Takahashi Y, Wozniak W. Flexural strength of In-Ceram alumina and In-Ceram zirconia core materials. Int J Prosthodont. 2002;15(2):183-8. Epub 2002/04/16. 40. Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci. 2007;115(2):161-6. Epub 2007/04/25. 41. Blatz MB, Sadan A, Kern M. Resin-ceramic bonding: a review of the literature. J Prosthet Dent. 2003;89(3):268-74. Epub 2003/03/20. 42. Kato H, Matsumura H, Atsuta M. Effect of etching and sandblasting on bond strength to sintered porcelain of unfilled resin. J Oral Rehabil. 2000;27(2):103-10. Epub 2000/02/15. 43. Osorio E, Toledano M, da Silveira BL, Osorio R. Effect of different surface treatments on In-Ceram Alumina roughness. An AFM study. J Dent. 2010;38(2):118-22. Epub 2009/10/01. 44. Kern M, Thompson VP. Bonding to glass infiltrated alumina ceramic: adhesive methods and their durability. J Prosthet Dent. 1995;73(3):240-9. Epub 1995/03/01. 45. Spohr AM, Borges GA, Junior LH, Mota EG, Oshima HM. Surface modification of In-Ceram Zirconia ceramic by Nd:YAG laser, Rocatec system, or aluminum oxide sandblasting and its bond strength to a resin cement. Photomedicine and laser surgery. 2008;26(3):203-8. Epub 2008/07/01. 46. Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns--validation of the silicone replica method. J Oral Rehabil. 2008;35(2):116-22. Epub 2008/01/17. 47. Borba M, Cesar PF, Griggs JA, Della Bona A. Adaptation of all-ceramic fixed partial dentures. Dent Mater. 2011;27(11):1119-26. Epub 2011/09/17. 48. Larson TD. The clinical significance of marginal fit. Northwest dentistry. 2012;91(1):22-9. Epub 2012/03/24. 49. Sulaiman F, Chai J, Jameson LM, Wozniak WT. A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns. The International journal of prosthodontics. 1997;10(5):478-84. Epub 1998/03/12. 50. Suarez MJ, Gonzalez de Villaumbrosia P, Pradies G, Lozano JF. Comparison of the marginal fit of Procera AllCeram crowns with two finish lines. Int J Prosthodont. 2003;16(3):229-32. Epub 2003/07/12. 51. Silness J, Loe H. Periodontal Disease in Pregnancy. Ii. Correlation between Oral Hygiene and Periodontal Condtion. Acta Odontol Scand. 1964;22:121-35. Epub 1964/02/01. 52. Loe H, Silness J. Periodontal Disease in Pregnancy. I. Prevalence and Severity. Acta Odontol Scand. 1963;21:533-51. Epub 1963/12/01. 53. Carranza F, Newman M. Periodontologia clínica. 8ª ed. Méjico: Mc Graw-Hill Interamericana; 1998. 54. Ryge G. The California Dental Association Quality Evaluation System: A Standard for Self-Assessment. Quality Evaluation of Dental Restorations: Criteria for Placement and Replacement. Chicago: Quintessence; 1989. 55. Valderhaug J. A 15-year clinical evaluation of fixed prosthodontics. Acta Odontol Scand. 1991;49(1):35-40. Epub 1991/02/01. 56. Walton TR. An up to 15-year longitudinal study of 515 metal-ceramic FPDs: Part 1. Outcome. Int J Prosthodont. 2002;15(5):439-45. Epub 2002/10/12. 57. Walton TR. An up to 15-year longitudinal study of 515 metal-ceramic FPDs: Part 2. Modes of failure and influence of various clinical characteristics. Int J Prosthodont. 2003;16(2):177-82. Epub 2003/05/10. 58. McLean JW. Evolution of dental ceramics in the twentieth century. J Prosthet Dent. 2001;85(1):61-6. Epub 2001/02/15. 59. Chu SJ. Evolution and clinical applications of esthetic ceramic materials in dentistry. J Am Dent Assoc. 2011;142 Suppl 2:3S. Epub 2011/04/06. 60. Kelly JR, Benetti P. Ceramic materials in dentistry: historical evolution and current practice. Australian dental journal. 2011;56 Suppl 1:84-96. Epub 2011/05/21. 61. Pjetursson BE, Sailer I, Zwahlen M, Hammerle CH. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res. 2007;18 Suppl 3:73-85. Epub 2007/06/28. 62. Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, et al. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent. 2006;96(4):237-44. Epub 2006/10/21. 63. Sailer I, Gottnerb J, Kanelb S, Hammerle CH. Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. Int J Prosthodont. 2009;22(6):553-60. Epub 2009/11/18. 64. Edelhoff D, Florian B, Florian W, Johnen C. HIP zirconia fixed partial dentures--clinical results after 3 years of clinical service. Quintessence Int. 2008;39(6):459-71. Epub 2008/12/06. 65. Beuer F, Stimmelmayr M, Gernet W, Edelhoff D, Guh JF, Naumann M. Prospective study of zirconia-based restorations: 3-year clinical results. Quintessence Int. 2010;41(8):631-7. Epub 2010/07/27. 66. Wolfart S, Harder S, Eschbach S, Lehmann F, Kern M. Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design. Eur J Oral Sci. 2009;117(6):741-9. Epub 2010/02/04. 67. Pelaez J, Cogolludo PG, Serrano B, Lozano JF, Suarez MJ. A prospective evaluation of zirconia posterior fixed dental prostheses: three-year clinical results. J Prosthet Dent. 2012;107(6):373-9. Epub 2012/05/29. 68. Leempoel PJ, Kayser AF, Van Rossum GM, De Haan AF. The survival rate of bridges. A study of 1674 bridges in 40 Dutch general practices. J Oral Rehabil. 1995;22(5):327-30. Epub 1995/05/01. 69. Blatz MB. Long-term clinical success of all-ceramic posterior restorations. Quintessence Int. 2002;33(6):415-26. Epub 2002/06/21. 70. Fradeani M, Aquilano A, Bassein L. Longitudinal study of pressed glass-ceramic inlays for four and a half years. J Prosthet Dent. 1997;78(4):346-53. Epub 1997/10/27. 71. Fradeani M, Redemagni M. An 11-year clinical evaluation of leucite-reinforced glass-ceramic crowns: a retrospective study. Quintessence Int. 2002;33(7):503-10. Epub 2002/08/09. 72. Fradeani M. The application of all-ceramic restorations in the anterior and posterior regions. Pract Proced Aesthet Dent. 2003;Suppl:13-7. Epub 2003/04/12. 73. Heintze SD, Rousson V. Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review. Int J Prosthodont. 2010;23(6):493-502. Epub 2011/01/07. 74. Bachhav VC, Aras MA. Zirconia-based fixed partial dentures: a clinical review. Quintessence Int. 2011;42(2):173-82. Epub 2011/03/02. 75. Anusavice KJ. Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses. Dent Mater. 2012;28(1):102-11. Epub 2011/12/24. 76. Schmitt J, Holst S, Wichmann M, Reich S, Gollner M, Hamel J. Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up. Int J Prosthodont. 2009;22(6):597-603. Epub 2009/11/18. 77. Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O. Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. J Oral Rehabil. 2009;36(8):610-5. Epub 2009/06/06. 78. Taskonak B, Yan J, Mecholsky JJ, Jr., Sertgoz A, Kocak A. Fractographic analyses of zirconia-based fixed partial dentures. Dent Mater. 2008;24(8):1077-82. Epub 2008/02/20. 79. Larsson C, Holm L, Lovgren N, Kokubo Y, Vult von Steyern P. Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study. J Oral Rehabil. 2007;34(9):702-9. Epub 2007/08/25. 80. Salido MP, Martinez-Rus F, Del Rio F, Pradies G, Ozcan M, Suarez MJ. Prospective Clinical Study of Zirconia-Based Posterior Four-Unit Fixed Dental Prostheses: Four-Year Follow-up. Int J Prosthodont. 2012;25(4):403-9. Epub 2012/06/22. 81. Martínez Rus F, Suárez García MJ, Serrano Madrigal B, Pradíes Ramiro G, Salido Rodríguez-Manzaneque MP. Evaluación clínica de puentes Procera® AllCeram. Resultados a 2 años. 2005;7(1):38-43. 82. Vult von Steyern P, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil. 2005;32(3):180-7. Epub 2005/02/15. 83. Holm C, Tidehag P, Tillberg A, Molin M. Longevity and quality of FPDs: a retrospective study of restorations 30, 20, and 10 years after insertion. Int J Prosthodont. 2003;16(3):283-9. Epub 2003/07/12. 84. Dundar M, Ozcan M, Comlekoglu E, Gungor MA, Artunc C. Bond strengths of veneering ceramics to reinforced ceramic core materials. Int J Prosthodont. 2005;18(1):71-2. Epub 2005/03/10. 85. Fischer J, Stawarczyk B, Tomic M, Strub JR, Hammerle CH. Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns. Dent Mater J. 2007;26(6):766-72. Epub 2008/01/22. 86. Aboushelib MN, Kleverlaan CJ, Feilzer AJ. Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: Zirconia veneering ceramics. Dent Mater. 2006;22(9):857-63. Epub 2005/12/27. 87. Aboushelib MN, de Kler M, van der Zel JM, Feilzer AJ. Effect of veneering method on the fracture and bond strength of bilayered zirconia restorations. Int J Prosthodont. 2008;21(3):237-40. Epub 2008/06/14. 88. Gunay H, Seeger A, Tschernitschek H, Geurtsen W. Placement of the preparation line and periodontal health--a prospective 2-year clinical study. Int J Periodontics Restorative Dent. 2000;20(2):171-81. Epub 2001/02/24. 89. Koke U, Sander C, Heinecke A, Muller HP. A possible influence of gingival dimensions on attachment loss and gingival recession following placement of artificial crowns. Int J Periodontics Restorative Dent. 2003;23(5):439-45. Epub 2003/11/19. 90. Schatzle M, Land NP, Anerud A, Boysen H, Burgin W, Loe H. The influence of margins of restorations of the periodontal tissues over 26 years. Journal of clinical periodontology. 2001;28(1):57-64. Epub 2001/01/06.