Publication:
Análisis in vitro de la resistencia a la fractura de puentes posteriores de óxido de circonio

Loading...
Thumbnail Image
Official URL
Full text at PDC
Publication Date
2012
Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Citations
Google Scholar
Research Projects
Organizational Units
Journal Issue
Abstract
Description
UCM subjects
Unesco subjects
Keywords
Citation
1. Suárez M J, López Lozano J F, Salido M P, Serrano B. Coronas de recubrimiento total cerámicas. Criterios de selección. Rev Europea de Odontoestomatología 1999;XI:249-258. 2. Fons A, Solá MF, Martínez-González A, Casas J. Clasificación actual de las cerámicas dentales. RCOE 2001;6.645-656 3. McLean J W. Evolution of dental ceramics in the twentieth century. J Prosthet Dent 2001:85:61-66. 4. Díaz-Romeral P, López E, Malumbres F, Gil L J. Porcelanas dentales de alta resistencia para restauraciones de recubrimiento total: Una revisión bibliográfica. Parte I. Revista Internacional de Prótesis Estomatológica 2008;10:19-31. 5. Romeo M, Martínez J A, Vallejo J. Introducción a los sistemas CAD/CAM de uso en clínica y laboratorio. Revista Internacional de Prótesis Estomatológica 2005;7:524:534. 6. Martínez F, Pradíes G, Suárez M J, Rivera B. Cerámicas dentales: clasificación y criterios de selección. RCOE 2007;12:253-263. 7. Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999;20:1-25. 8. Manicone PF, Iommetti PR, Raffaelli L. An overview of zirconia ceramics: Basic properties and clinical applications. J Dent 2007;35:819-826 9. Suttor D. Lava zirconia crowns and bridges. Int J Comput Dent 2004;7(1):67-76. 10. Garvie R C, Hannink RH, Pascoe RT. Ceramic steel? Nature 1975;258:703-704 11. Duke E S. The status of CAD/CAM in restorative dentistry. Compendium 2001;22:968-972. 12. Kurbad A. Clinical aspects of all-ceramic CAD/CAM restorations. Int J Comput Dent 2002; 5: 183-97. 13. Liu PR. A panorama of dental CAD/CAM restorative systems. Compend Contin Educ Dent 2005; 26: 507-8, 510, 512 passim; quiz 517, 527. 14. Raigrodski AJ. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2004;92(6):557-62. 15. Miyazaki T, Hotta Y. CAD/CAM systems available for the fabrication of crown and bridge restorations. Australian Dent J 2011;56:97-106 16. Gonzalo E. Estudio experimental del sellado marginal en puentes posteriores de óxido de circonio. Tesis Doctoral : Universidad Complutense de Madrid ; 2007. 17. Martínez F. Estudio experimental del ajuste marginal en coronas cerámicas de alto contenido en circonia. Tesis Doctoral: Universidad Complutense de Madrid; 2005. 18. Fasbinder D J. Restorative material options for CAD/CAM restorations. Compendium 2002;23:911-922. 19. Filser F, Kocher P, Weibel F, Luthy H, Scharer P, Gauckler LJ. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent 2001;4(2):89-106. 20. Persson M, Andersson M, Bergman B. The accuracy of a high precision digitizer for CAD/CAM of crowns. J Prosthet Dent 1995;74:223-229. 21. Persson A S K, Andersson M, Odén A, Sandborgh-Englund. Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology. Dent Mat 2008;24:1123-1130. 22. Luthardt R G, Bornemann G, Lemelson S, Walter M H, Hüls A. An innovative method for evaluation of the 3D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing. Int J Prosthodont 2004;17:680-685 23. Luthardt R G, Sandkohl O, Herold V, Walter M H. Accuracy of the mechanical digitizing with a CAD/CAM system fixed restorations. Int J Prosthodont 2001;14:146-151. 24. Quaas S, Rudolph H, Luthardt R G. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 2007;35:903-908. 25. Gonzalo E, Suárez MJ, Serrano B, L Lozano JF. Marginal fit of posterior Zirconio FPDs. Int J Prosthodont 2008;21:398-399 26. Gonzalo E, Suárez M J, Serrano B, L Lozano J F. A comparison of the marginal vertical discrepancies of zirconium and metal-ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent 2009;102:378-384 27. Martínez-Rus F, Suárez M J, Rivera B, Pradíes G. Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings. J Prosthet Dent 2011;105:108-114 28. Vega JM. Materiales en Odontología: Fundamentos biológicos, clínicos, biofísicos y físico-químicos. Madrid: Avances; 1996. 29. Fischer H, Rentzsch W, Marx R. R-curve behavior of dental ceramic materials. J Dent Res 2002;81:547-51. 30. Serrano Madrigal B. Estudio experimental de la resistencia a la fractura de puentes totalmente cerámicos. Tesis Doctoral: UCM; 2005. 31. ZengK, Oden A, Rowcliffe D. Evaluación de las propiedades mecánicas de los materiales de los núcleos cerámicos en combinación con porcelanas. Rev Int de Prótesis Estomatológica 1999; 1: 161-175. 32. Acevedo R. Análisis del sellado marginal y la resistencia a la fractura de núcleos cerámicos de óxido de circonio en puentes posteriores. Tesis Doctoral: UCM; 2011. 33. Attia A, Kern M. Influence of cyclic loading and luting agents on the fracture load of two all-ceramic crown systems. J Prosthet Dent 2004;92(6):551-6. 34. Fischer H, Dautzenberg G, Marx R. Nondestructive estimation of the strength of dental ceramic materials. Dent Mater 2001;17(4):289-95. 35. Al-Dohan HM, Yaman P, Dennison JB, Razzoog ME, Lang BR. Shear strength of core-veneer interface in bi-layered ceramics. J Prosthet Dent 2004;91(4):349-55. 36. Waltimo A, Kemppainen P, Kononen M. Maximal contraction force and endurance of human jaw-closing muscles in isometric clenching. Scand J Dent Res 1993;101(6):416-21. 37. Rosentritt M, Behr M, Handel G. Fixed partial dentures: all-ceramics, fibrereinforced composites and experimental systems. J Oral Rehabil 2003;30(9):873-7. 38. Attia A, Kern M. Fracture strength of all-ceramic crowns luted using two bonding methods. J Prosthet Dent 2004;91(3):247-52. 39. Seghi RR, Denry IL, Rosenstiel SF. Relative fracture toughness and hardness of new dental ceramics. J Prosthet Dent 1995;74(2):145-50. 40. Potiket N, Chiche G, Finger IM. In vitro fracture strength of teeth restored with different all-ceramic crown systems. J Prosthet Dent 2004;92(5):491-495. 41. Schmitt J, Holst S, Wichmann M, Reich S, Gollner M, Hamel J. Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up. Int J Prosthodont 2009;22(6):597-603. 42. Molin MK, Karlsson SL. Five-year clinical prospective evaluation of zirconiabased Denzir 3-unit FPDs. Int J Prosthodont 2008;21(3):223-7. 43. Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 2008;21(3):217-22. 44. Ozcan M, Vallittu PK. Effect of surface conditioning methods on the bond strength of luting cement to ceramics. Dent Mater 2003;19(8):725-31. 45. Ghazy MH, Madina MM. Fracture resistance of metal- and galvano-ceramic crowns cemented with different luting cements: in vitro comparative study. Int J Prosthodont 2006;19(6):610-2. 46. Hondrum SO. A review of the strength properties of dental ceramics. J Prosthet Dent 1992;67(6):859-65. 47. Tsalouchou E, Cattell MJ, Knowles JC, Pittayachawan P, McDonald A. Fatigue and fracture properties of yttria partially stabilized zirconia crown systems. Dent Mater 2008;24(3):308-18. 48. Reitemeier B, Hansel K, Kastner C, Walter MH. Metal-ceramic failure in noble metal crowns: 7-year results of a prospective clinical trial in private practices. Int J Prosthodont 2006;19(4):397-9. 49. Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications in fixed prosthodontics. J Prosthet Dent 2003;90(1):31-41. 50. Pallis K, Griggs JA, Woody RD, Guillen GE, Miller AW. Fracture resistance of three all-ceramic restorative systems for posterior applications. J Prosthet Dent 2004;91(6):561-9. 51. Sundh A, Molin M, Sjogren G. Fracture resistance of yttrium oxide partiallystabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing. Dent Mater 2005;21(5):476-82. 52. Oh W, Gotzen N, Anusavice KJ. Influence of connector design on fracture probability of ceramic fixed-partial dentures. J Dent Res 2002;81(9):623-7. 53. Taskonak B, Mecholsky JJ, Jr., Anusavice KJ. Fracture surface analysis of clinically failed fixed partial dentures. J Dent Res 2006;85(3):277-81. 54. Taskonak B, Yan J, Mecholsky JJ, Jr., Sertgoz A, Kocak A. Fractographic analyses of zirconia-based fixed partial dentures. Dent Mater 2008;24(8):1077-82. 55. Ozen J, Caglar A, Beydemir B, Aydin C, Dalkiz M. Three-dimensional finite element stress analysis of different core materials in maxillary implant-supported fixed partial dentures. Quintessence Int 2007;38(6):e355-63. 56. Guazzato M, Proos K, Sara G, Swain MV. Strength, reliability, and mode of fracture of bilayered porcelain/core ceramics. Int J Prosthodont 2004;17(2):142- 149. 57. Studart AR, Filser F, Kocher P, Gauckler LJ. Fatigue of zirconia under cyclic loading in water and its implications for the design of dental bridges. Dent Mater 2007;23(1):106-14. 58. Larsson C, Holm L, Lovgren N, Kokubo Y, Vult von Steyern P. Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study. J Oral Rehabil 2007;34(9):702-9. 59. Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont 2001;14(3):231-8. 60. Raptis NV, Michalakis KX, Hirayama H. Optical behavior of current ceramic systems. Int J Periodontics Restorative Dent 2006;26:31-41 61. Salido MP, Suárez MJ, Pradíes G, Caruana G. Análisis comparativo del ajuste marginal en coronas cerámicas. Rev Int Prót Est 2000;2(3):225-32. 62. Suárez M J, González de Villaumbrosia P, Pradíes G, L Lozano J F. Comparison of the marginal fit of Procera AllCeram crowns with two finish lines. Int J Prosthodont 2003;16:229-232. 63. Quintas AF, Oliveira F, Bottino MA. Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation. J Prosthet Dent 2004;92(3):250-7. 64. Suttor D, Bunke K, Hoescheler S, Hauptmann H, Hertlein G. LAVA--the system for all-ceramic ZrO2 crown and bridge frameworks. Int J Comput Dent 2001;4:195-206. 65. Kunii J, Hotta Y, Tamaki Y, Ozawa, Kobayashi Y et al. Effect of sintering on the marginal and internal fit of CAD/CAM fabricated zirconia frameworks. Dent Mater J 2007;26:820-826 66. Chen HY, Hickel R, Setcos JC, Kunzelmann KH. Effects of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns. J Prosthet Dent 1999;82(4):468-75. 67. Oh SC, Dong JK, Luthy H, Scharer P. Strength and microstructure of IPS Empress 2 glass-ceramic after different treatments. Int J Prosthodont 2000;13(6):468-72. 68. Iseri U, Ozkurt Z, Kazazoglu E, Kucukoglu D. Influence of grinding procedures on the flexural strength of zirconia ceramics. Braz Dent J 2010;21:528-32. 69. Jung YG, Peterson IM, Kim DK, Lawn BR. Lifetime-limiting strength degradation from contact fatigue in dental ceramics. J Dent Res 2000;79:722-31. 70. Zhang Y, Lawn BR, Malament KA, Van Thompson P, Rekow ED. Damage accumlation and fatigue life of particle-abraded ceramics. Int J Prosthodont 2006;1:442-8. 71. Kohorst P, Dittmer MP, Borchers L, Stiesch-Scholz M. Influence of cyclic fatigue in water on the load-bearing capacity of dental bridges made of zirconia. Acta Biomater 2008;4:1440-7. 72. Ardlin BI. Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of low-temperature aging on flexural strength and surface structure. Dent Mater 2002;18(8):590-5. 73. Sundh A, Sjögren G. Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering. Dent Mater 2006;22:778-784 74. Borchers L, Stiesch M, Bach FW, Buhl JC, Hubsch C, Kellner T, et al. Influence of hydrothermal and mechanical conditions on the strength of zirconia. Acta Biomater 2010;6(12):4547-52. 75. Curtis AR, Wright AJ, Fleming GJ. The influence of simulated masticatory loading regimes on the bi-axial flexure strength and reliability of a Y-TZP dental ceramic. J Dent 2006;34(5):317-25. 76. Ashkanani HM, Raigrodski AJ, Flinn BD, Heindl H, Mancl LA. Flexural and shear strengths of ZrO2 and a High-Noble Alloy Bonded to their corresponding porcelains. J Prosthet Dent 2008;100:274-284. 77. Papanagiotou HP, Morgano SM, Giordano RA, Pober R. In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics. J Prosthet Dent 2006;96:154-64. 78. Shearer B, Gough MB, Setchell DJ. Influence of marginal configuration and porcelain addition on the fit of In-Ceram crowns. Biomaterials 1996;17(19):1891-5. 79. Snyder MD, Sierraalta M, Razzoog ME. Load of fractures of veneered zirconia material. [abstr 451]. J Dent Res 2003;82(Spec Iss B):194. 80. Sundh A, Sjogren G. A comparison of fracture strength of yttrium-oxidepartially-stabilized zirconia ceramic crowns with varying core thickness, shapes and veneer ceramics. J Oral Rehabil 2004;31:682-8. 81. Studart AR, Filser F, Kocher P, Lüthy H, Gauckler LJ. Ciclic fatigue in water of veneer-framework composites for all-ceramic dental bridges. Dent Mater 2007;23:177-185 82. Borba M, de Araujo MD, de Lima E, Yoshimura HN, Cesar PF, Griggs JA, Della Bona A. Flexural strength and failure modes of layered ceramic structures. Dent Mater 201;27:1259-1266 83. Studart AR, Filser F, Kocher P, Lüthy H, Gauckler LJ. Mechanical and fracture behavior of veneered-framework composites for all-ceramic dental bridges. Dent Mater 2007;23:115-123 84. Luthy H, Fiser F, Loeffel O, Schumacher M, Gauckler Lj, Hammerle CH. Strength and reliability of four-unit all-ceramic posterior bridges. Dent Mater 2005;21:930-937 85. Rosentritt M, Behr M, R L, S K, G H. Fracture Strength of tooth colored posterior fixed partial dentures. J Dent Res 2001;80:57. 86. Stiesch-Scholz M, Scheneemann P, Borchers L. In vitro fracture resistance of 4-unit all-ceramic fixed partial dentures. IADR abstracts 2005 (Abstract # 0555). 87. Ludwig K, M K, S K. Fracture Strength of all-ceramic anterior fixed partial dentures. J Dent Res 2001;80 (Special Issue IADR Abstracts # 998) 88. Suttor D, Hauptmann H, Frank S, Hoescheler S. Fracture resistance of posterior all ceramic zirconia bridges. J Dent Res 2001;80:640. 89. Rountree P, Nothdurft F, Pospiech P. In-vitro-investigations on the fracture strength of all-ceramic posterior bridges of ZrO2-ceramic. J Dent Res 2001;80:57 90. Chevalier J, Cales B, Drouin JM. Low temperature aging of Y-TZP ceramics. J Am Ceram Soc 1999;82:2150-2154 91. Fisher J, Stawarczyk B, Trottmann A Hämmerle CHF. Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites. Dent Mater 2009;25:419-423. 92. Fischer J, Stawarczyk B, Hämmerle CHF. Flexural strength of veneering ceramics for zirconia. J Dent 2008;36:316-321 93. Rosentritt M, Steiger D, Behr M, Handel G, Kolbeck C. Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. J Dent 2009;37:978-983 94. Aboushelib MN, Kleverlaan CJ, Feilzer AJ. Effect of zirconia type on its bond strength wit different veneer ceramics. J Prosthodont 2008;17:401-408 95. Hsueh CH, Thompson GA, Jadaan OM, Wereszczak AA, Becher PF. Analyses of layer-thickness effects in bilayered dental ceramics subjected to thermal stresses and ring-on-ring tests. Dent Mater 2008;24:9-17 96. Fisher J, Grohmann P, Stawarczyk B. Effect of zirconia surface treatments on the shear strength of zirconia/veneering ceramic composites. Dent Mater J 2008;27:448-454. 97. Zhang Y, Lawn BR, Rekow ED, Thompson VP. Effect of sandblasting on the long-term performance of dental ceramics. J Biomed Mater Res B Appl Biomater 2004;15:381-386 98. Guazzato M, Quach L, Albakry M, Swain MV. Influence of surface and heat treatments on the flexural strength of Y-TZP dental ceramic. J Dent 2005;33:9-18. 99. Tanaka R, Fujishima A, Shibata Y, Manabe A, Miyazaki T. Cooperation of phosphate monomer and silica modification on zirconia. J Dent Res 2008;87:666-670. 100. Tanaka K, Tamura J, Kawanabe K, Nawa M, Oka M, Uchida M et al. Ce-TZP/A1203 nanocomposite as bearing material in total joint replacement. J Biomed Mater Re 2002;63:262-270 101. Cales B. Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop Relat Res 2000;379:94-112 102. Sailer I, Fehér A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 2007;20:383-8 103. Kim JW, Kim JH, Janal MN, Zhang Y. Damage maps of veneered zirconia under simulated mastication. J Dent Res 2008;87:1127-1132 104. Allahkarami M, Hanan JC. Mapping the tetragonal to monoclinic phase transformation in zirconia core dental crowns. Dent Mater 2011;27:1279-1284