Rad-Tol Pt-100 isolation amplifiers for the LHC cryogenic system

Impacto

Downloads

Downloads per month over past year

Agapito Serrano, Juan Andrés and Casas-Cubillos, Juan and Fernandes, Ana C. and Franco Peláez, Francisco Javier and Gonçalves, Isabel and Hernández Cachero, Antonio and Marques, José G. and Rodríguez-Ruiz, Miguel Ángel and Zong, Yi (2004) Rad-Tol Pt-100 isolation amplifiers for the LHC cryogenic system. In Proceedings of the tenth Workshop on Electronics for LHC Experiments. CERN Publishing Service, Geneva, Switzerland, pp. 117-121. ISBN 92-9083-237-1

[img]
Preview
PDF
Creative Commons Attribution.

438kB

Official URL: http://dx.doi.org/10.5170/CERN-2004-010.402




Abstract

The cryogenic system of the LHC will use Pt-100 sensors to measure temperatures between 40-300K and isolation devices will be used. The selected commercial components must be rad-tolerant since a total radiation dose of 5E12 n/cm2 &100 Gy is expected during ten years of the LHC lifetime. Neutron tests in this family of devices were performed and the results are shown in this paper.