High AC/A Accommodative Esotropia Strabismus Treated with Contact Lenses: A Single Case Design (N=1) Study

Impacto

Downloads

Downloads per month over past year



González Díaz-Obregón, Enrique and Barra Lázaro, Francisco and Sánchez Pérez, Isabel and Antona Peñalba, Beatriz and Barrio de Santos, Ana Rosa (2007) High AC/A Accommodative Esotropia Strabismus Treated with Contact Lenses: A Single Case Design (N=1) Study. Binocular vision & strabismus quarterly, 22 (2). pp. 90-95. ISSN 1088-6281

[img] PDF
Restringido a Repository staff only

438kB



Abstract

BACKGROUND AND PURPOSE: The purpose was to determine the efficacy of two types of contact lenses (spherical disposable and aplanatic) as treatment in a patient with esotropia with a high Accommodative Convergence/Accommodation Ratio (AC/A). Due to the possibility of the appearance of accommodative insufficiency in this kind of patient, (i.e., following many years of bifocal glasses use), the elimination of the plus addition lens is advisable. Nevertheless, in some patients, this change leads to the appearance of a residual angle of esodeviation in near vision. It was expected that monofocal aplanatic contact lenses could achieve, due to their optical characteristics, an accurate and orthotropic binocular alignment, without aggravating an undesirable manifestation of the accommodative insufficiency.
METHODS: An experimental design of a single case (N=1) was used in which the subject acted as his own control. With bifocal glasses the subject displayed stability in his binocular and accommodative system at every distance of vision for the past three years. We compared the efficacy of two different types of hydrophilic contact lenses to control the angle of deviation, both at distance and at near vision.
RESULTS: Neither of the two contact lenses produced the results of stability and the correct binocular alignment that had been achieved with bifocal glasses. This subject experienced a worse manifest esodeviation in distance vision with aplanatic lenses than with the disposable ones.
CONCLUSIONS: These monofocal contact lenses did not create acceptable binocular alignment and stability in a subject with a high AC/A accommodative esotropia.


Item Type:Article
Additional Information:

Versión preprint del artículo publicado

COPYRIGHT 2012. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,electronic or mechanical, including xerographic copy, photocopy, recording, or an information storage and retrieval system,without permission in writing from the publisher, except as specifically allowed by law (each paid subscriber may print one hard copy of each issue, for personal use only, by simply executing the “print” command on their computer/printer).

Uncontrolled Keywords:Esotropia ; Strabismus ; Contact Lenses ; Accommodation ocular ; Visual Acuity
Subjects:Medical sciences > Medicine > Optics
Medical sciences > Optics > Contact lenses
Medical sciences > Optics > Visual perception
ID Code:33900
Deposited On:06 Nov 2015 09:45
Last Modified:06 Nov 2015 09:45

Origin of downloads

Repository Staff Only: item control page