Aniseikonia tests: The role of viewing mode, response bias, and size-color illusions.

Impacto

Downloads

Downloads per month over past year



García-Pérez, Miguel A. and Peli, Eli (2015) Aniseikonia tests: The role of viewing mode, response bias, and size-color illusions. Translational vision science & technology, 4 (3). ISSN 2164-2591

[img]
Preview
PDF
Creative Commons Attribution.

2MB

Official URL: http://dx.doi:10.1167/tvst.4.3.9



Abstract

PURPOSE

To identify the factors responsible for the poor validity of the most common aniseikonia tests, which involve size comparisons of red-green stimuli presented haploscopically.

METHODS

Aniseikonia was induced by afocal size lenses placed before one eye. Observers compared the sizes of semicircles presented haploscopically via color filters. The main factor under study was viewing mode (free viewing versus short presentations under central fixation). To eliminate response bias, a three-response format allowed observers to respond if the left, the right, or neither semicircle appeared larger than the other. To control decisional (criterion) bias, measurements were taken with the lens-magnified stimulus placed on the left and on the right. To control for size-color illusions, measurements were made with color filters in both arrangements before the eyes and under binocular vision (without color filters).

RESULTS

Free viewing resulted in a systematic underestimation of lens-induced aniseikonia that was absent with short presentations. Significant size-color illusions and decisional biases were found that would be mistaken for aniseikonia unless appropriate action is taken.

CONCLUSIONS

To improve their validity, aniseikonia tests should use short presentations and include control conditions to prevent contamination from decisional/response biases. If anaglyphs are used, presence of size-color illusions must be checked for.

TRANSLATIONAL RELEVANCE

We identified optimal conditions for administration of aniseikonia tests and appropriate action for differential diagnosis of aniseikonia in the presence of response biases or size-color illusions. Our study has clinical implications for aniseikonia management.


Item Type:Article
Uncontrolled Keywords:Aniseikonia, Eye movements, Size perception, Vernier acuity, Size-color illusion
Subjects:Medical sciences > Psychology > Perception
Medical sciences > Optics > Eyes anatomy
Medical sciences > Optics > Physiological optics