Universidad Complutense de Madrid
E-Prints Complutense

Changes in Diadenosine Polyphosphates during Alignment-Fit and Orthokeratology Rigid Gas Permeable

Impacto

Downloads

Downloads per month over past year

Carracedo Rodríguez, Juan Gonzalo and González-Méijome, José Manuel and Pintor, Jesús (2012) Changes in Diadenosine Polyphosphates during Alignment-Fit and Orthokeratology Rigid Gas Permeable. Investigative Ophthalmology & Visual Science, 53 (7). pp. 4426-4432. ISSN 0146-0404

[img]
Preview
PDF
Creative Commons Attribution Non-commercial No Derivatives.

374kB

Official URL: http://dx.doi.org/10.1167/iovs.11-9342




Abstract

Purpose.: To evaluate the levels of dinucleotides diadenosine tetraphosphate (Ap4A) and diadenosine pentaphosphate (Ap5A) in tears of patients wearing rigid gas permeable (RGP) contact lenses on a daily wear basis and of patients wearing reverse-geometry RGP lenses overnight for orthokeratology treatment.
Methods.: Twenty-two young volunteers (10 females, 12 males; 23.47 ± 4.49 years) were fitted with an alignment-fit RGP lens (paflufocon B) for a month, and after a 15-day washout period they were fitted with reverse-geometry RGP lenses for corneal reshaping (paflufocon D) for another month. During each period, tears were collected at baseline day 1, 7, 15, and 28. Ap4A and Ap5A were measured by high-pressure liquid chromatography (HPLC). Additionally, corneal staining, break-up time (BUT), Schirmer test, and dryness symptoms were evaluated.
Results.: Ap4A concentrations increased significantly from baseline during the whole period of daily wear of RGP lenses (P < 0.001); concentration was also significantly higher than in the orthokeratology group, which remained at baseline levels during the study period except at day 1 (P < 0.001) and day 28 (P = 0.041). While BUT and Schirmer remained unchanged in both groups, discomfort and dryness were significantly increased during alignment-fit RGP daily wear but not during the orthokeratology period.
Conclusions.: Daily wear of RGP lenses increased the levels of Ap4A due to mechanical stimulation by blinking of the corneal epithelium, and this is associated with discomfort. Also, orthokeratology did not produce symptoms or signs of ocular dryness, which could be a potential advantage over soft contact lenses in terms of contact lens-induced dryness.


Item Type:Article
Additional Information:

En O.A. en la web del editor

Uncontrolled Keywords:Eye disorders ; Low visions ; Cornea; Lens ; Diadenosine poliphosphates ; Orthokerathology
Subjects:Sciences > Chemistry > Biochemistry
Medical sciences > Medicine > Surgery
Medical sciences > Medicine > Ophtalmology
Medical sciences > Optics > Visual perception
ID Code:39567
Deposited On:24 Oct 2016 08:31
Last Modified:07 Nov 2016 18:25

Origin of downloads

Repository Staff Only: item control page