Universidad Complutense de Madrid
E-Prints Complutense

Capacity of straylight and disk halo size to diagnose cataract

Impacto

Downloads

Downloads per month over past year

Palomo Álvarez, Catalina and Puell Marín, María Cinta (2015) Capacity of straylight and disk halo size to diagnose cataract. Journal of cataract and refractive surgery, 41 (10). pp. 2069-2074. ISSN 1873-4502

[img] PDF
Restringido a Repository staff only

317kB

Official URL: http://dx.doi.org/10.1016/j.jcrs.2015.10.047



Abstract

Purpose To examine the capacity of straylight and disk halo size to diagnose cataract. Setting Faculty of Optics and Optometry, Universidad Complutense de Madrid, Spain. Design Prospective study. Methods Straylight, disk halo radius, and high-contrast corrected distance visual acuity (CDVA) measurements were compared between patients with age-related cataract and age-matched normal-sighted control subjects by calculating the area under the curve (AUC) receiver operating characteristic. Results Measurements were made in 53 eyes of 53 patients with a mean age of 67.94 years ± 7.11 (SD) and 31 eyes of 31 controls with a mean age 66.06 ± 5.43 years. Significantly worse (P <.001) mean straylight (1.38 ± 0.24 log[s]), mean disk halo radius (2.40 ± 0.18 log minutes of arc [arcmin]), and mean CDVA (0.17 ± 0.11 logMAR) were recorded in the cataract group than in the control group (1.17 ± 0.11 log[s], 2.10 ± 0.16 log arcmin, and 0.08 ± 0.08 logMAR). Significant differences in AUCs were observed for disk halo radius (0.89 ± 0.04) versus straylight (0.77 ± 0.05) (P =.03) and disk halo radius versus CDVA (0.72 ± 0.05) (P =.001). The comparison of disk halo radius versus the discriminant function with input from CDVA and straylight (0.80 ± 0.05) was at the limit of significance only (0.091 ± 0.05, P =.051). Conclusion Although all 3 variables discriminated well between normal eyes and eyes with cataract, the disk halo radius showed the best diagnostic capacity. Financial Disclosure Neither author has a financial or proprietary interest in any material or method mentioned.


Item Type:Article
Additional Information:

Submitted: November 20, 2014.
Final revision submitted: March 20, 2015.
Accepted: March 22, 2015.

Uncontrolled Keywords:Cataract ; Diagnostic techniques ; Visual acuity ; Scattering ; Straylight ; Halo size
Subjects:Medical sciences > Medicine > Ophtalmology
Medical sciences > Optics > Optometry
ID Code:40993
Deposited On:26 Jan 2017 09:20
Last Modified:26 Jan 2017 09:20

Origin of downloads

Repository Staff Only: item control page