Morphometry of the trabecular meshwork in vivo in a healthy population using fourier-domain optical coherence tomography

Impacto

Downloads

Downloads per month over past year

Fernández Vigo, José Ignacio and García Feijoo, Julián and Martínez de la Casa, Jose Maria and García Bella, Javier and Fernández Vigo, José Ángel (2015) Morphometry of the trabecular meshwork in vivo in a healthy population using fourier-domain optical coherence tomography. Investigative Ophthalmology & Visual Science, 56 (3). pp. 1782-1788. ISSN 0146-0404

[img]
Preview
PDF
Creative Commons Attribution Non-commercial No Derivatives.

758kB

Official URL: http://dx.doi.org/10.1167/iovs.14-16154



Abstract

PURPOSE. We measured the length, thickness, and area of the trabecular meshwork (TM) in vivo using Fourier domain optical coherence tomography (FD-OCT) in a Caucasian population of healthy subjects.
METHODS. A cross-sectional study was done of 1006 healthy subjects. Left eyes were randomly selected. Age, sex, IOP, and spherical refractive error were noted. The depth and volume of the anterior chamber and the central corneal thickness were measured with Pentacam, while IOL Master was used to measure the axial length. The length, thickness, and area of the TM were measured through FD-OCT RTVue. A study was done to determine the correlation between TM size, and other demographic and ocular parameters. Finally, the reproducibility of the measurements was assessed for a subgroup of 50 eyes from 50 patients.
RESULTS. We were able to measure the TM in 91.1% of the total eyes studied. The mean TM length was 496.99 6 92.77 lm (range, 275–800), TM thickness was 174.16 6 28.14 lm (range, 100–276), and TM area was 0.069 6 0.031 mm2 (range, 0.023–0.133). No differences were found in terms of length and area for sex, although the TM was slightly thicker in men (P ¼ 0.046). No correlation was observed between the TM measurements and any of the studied demographic or ocular parameters (R < 0.09, P < 0.001). Intra- and interobserver reproducibility of the measurements were good (intraclass correlation coefficient > 0.750, P < 0.001).
CONCLUSIONS. The FD-OCT is an effective and reproducible examination technique to measure the length, thickness, and area of the TM in vivo.


Item Type:Article
Additional Information:

En abierto en la web del editor.
ISSN: 1552-5783 (versión electrónica)
Submitted: November 27, 2014 / Accepted: February 11, 2015

Uncontrolled Keywords:Trabecular meshwork, Optical coherence tomography, Glaucoma anterior segment
Subjects:Medical sciences > Medicine > Ophtalmology
Medical sciences > Optics > Geometrical and instumental optics
Medical sciences > Optics > Imaging systems
ID Code:40999
Deposited On:26 Jan 2017 09:04
Last Modified:26 Jan 2017 11:06

Origin of downloads