Papadatou, Eleni y Águila Carrasco, Antonio J. Del y Esteve Taboada, José J. y Madrid Costa, David y Cerviño Expósito, Alejandro (2017) Objective assessment of the effect of pupil size upon the power distribution of multifocal contact lenses. International journal of Ophthalmology, 10 (1). pp. 103-108. ISSN 2222-3959

[img]
Vista previa
PDF
Creative Commons License
Esta obra está bajo una licencia de Creative Commons: Reconocimiento.

1MB

URL Oficial: http://www.ijo.cn/gjyken/ch/first_menu.aspx?parent_id=20120104165221001



Resumen

AIM: To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses.
METHODS: Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed.

RESULTS: The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about ?3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens.

CONCLUSION: In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient’s visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome.


Tipo de documento:Artículo
Información Adicional:

Open Access en el editor

Palabras clave:Multifocal contact lenses; Pupil size; Refractive power distribution; Poer profiles
Materias:Ciencias Biomédicas > Medicina > Oftalmología
Ciencias Biomédicas > Óptica y optometría > Lentes de contacto
Código ID:42412
Depositado:03 May 2017 13:37
Última Modificación:03 May 2017 14:37

Descargas en el último año

Sólo personal del repositorio: página de control del artículo