Characterization of Corneoscleral Geometry Using Fourier Transform Profilometry in the Healthy Eye

Impacto

Downloads

Downloads per month over past year

Piñero, David Pablo and Martínez Abad, Antonio and Soto Negro, Roberto and Ariza Gracia, Miguel Ángel and Carracedo Rodríguez, Juan Gonzalo (2019) Characterization of Corneoscleral Geometry Using Fourier Transform Profilometry in the Healthy Eye. Eye & Contact Lens: Science & Clinical Practice, 45 (3). pp. 201-207. ISSN 1542-2321

[img] PDF
Restringido a Repository staff only

456kB

Official URL: http://dx.doi.org/10.1097/ICL.0000000000000560




Abstract

Objective: To characterize peculiarities of the corneoscleral geometry in healthy eyes.
Methods: This is a prospective case series including 88 healthy eyes of 88 patients with an age ranging from 21 to 73 years. A complete ocular examination was performed with emphasis on the analysis of the corneoscleral topographic profile with the Fourier transform profilometer Eye Surface Profiler (Eaglet-Eye BV, Houten, the Netherlands). The distribution of different topographic parameters was evaluated, as well as the correlations between corneal and scleroconjunctival parameters.
Results: Mean values of 8.64±0.37 (range, 7.81–9.50 mm), 6.06±0.52 (4.88–7.63 mm) and 11.93±1.32 mm (8.17–15.89 mm) were obtained for inner, limbal, and outer best-fit sphere, respectively. Mean values of 8.54±0.38 (7.86–9.66 mm) and 13.35±1.29 mm (11.05–17.31 mm) were obtained for mean corneal and scleral radius, respectively. Regarding tangent angles at limbus, mean values of 35.31±6.55°, 38.76±5.90°, 32.75±7.04°, and 25.91±8.99° were obtained for nasal, temporal, superior, and inferior angles, respectively. Mean difference between temporal and nasal sagittal heights increased from −1.48±120.70 μm for a chord of 11 mm to 73.53±236.55 μm for a chord of 14 mm. A weak but statistically significant correlation was found between corneal and scleral radii (r=0.325, P=0.004). The maximum sagittal height for a diameter of 12 mm was significantly correlated with flattest keratometry, astigmatism, corneal diameter, and corneal eccentricity (R2: 0.77, P<0.001).
Conclusions: The scleroconjunctival surface in the healthy eye presents some level of nasotemporal asymmetry that is higher with increasing diameters of analysis.


Item Type:Article
Additional Information:

Accepted September 24, 2018

Uncontrolled Keywords:Fourier transform profilometer,Corneoscleral topography,Scleral radius,Eye sagittal height,Eye surface profiler
Subjects:Medical sciences > Optics > Visual perception
Medical sciences > Optics > Eyes anatomy