Universidad Complutense de Madrid
E-Prints Complutense

Visual quality and patient satisfaction with a trifocal intraocular lens and its new toric version

Impacto

Downloads

Downloads per month over past year

Rementería Capelo, Laureano A and Contreras Martín, Inés and García Pérez, Jorge L. and Blázquez Sánchez, Vanesa and Ruiz Alcocer, Javier (2019) Visual quality and patient satisfaction with a trifocal intraocular lens and its new toric version. Journal of cataract and refractive surgery, 45 (11). pp. 1584-1590. ISSN 1873-4502

[img] PDF
Restringido a Repository staff only

699kB

Official URL: https://doi.org/10.1016/j.jcrs.2019.06.014




Abstract

Purpose: To assess and compare the visual quality and subjective outcomes of a trifocal spherical intraocular lens (IOL) and its new toric version.
Setting: Clínica Rementería, Madrid, Spain.
Design: Prospective case series.
Methods: Patients had bilateral implantation of the AcrySof IQ PanOptix spherical or toric IOL. Three months postoperatively, monocular and the binocular uncorrected and corrected distance, intermediate, and near visual acuities; binocular defocus curves; and binocular contrast sensitivity function (CSF) were assessed. Patient satisfaction was evaluated with the Catquest 9SF questionnaire.
Results: The study comprised 250 eyes (166 with spherical IOL; 84 with toric IOL) of 125 patients. Both groups had good monocular visual acuity at all distances with no statistically significant differences between groups. The mean monocular uncorrected acuity in the spherical group was 0.06 logarithm of the minimum angle of resolution (logMAR) ± 0.07 (SD), 0.20 ± 0.10 logMAR, and 0.05 ± 0.07 logMAR for far, intermediate, and near, respectively, and in the toric group, 0.07 ± 0.10 logMAR, 0.23 ± 0.20 logMAR, and 0.07 ± 0.12 logMAR, respectively. Defocus curves showed a visual acuity of 0.1 logMAR or better between −2.5 diopters (D) and +0.5 D with no differences between groups. The CSF values were within normal ranges with both IOLs. The questionnaire showed high rates of patient satisfaction with no differences between groups.
Conclusions: The visual outcomes with the 2 IOLs were similar. With optimum implantation and alignment, the trifocal toric IOL seems to provide visual quality and patient satisfaction that is equivalent to that with the nontoric version with the same platform.


Item Type:Article
Additional Information:

Received 26 March 2019, Revised 13 June 2019, Accepted 17 June 2019, Available online 3 October 2019.

Uncontrolled Keywords:Visual quality; Intraocular lens; IOLs; Trifocal intraocular lens; Toric lens
Subjects:Medical sciences > Medicine > Surgery
Medical sciences > Optics > Contact lenses
Medical sciences > Optics > Visual perception
ID Code:60763
Deposited On:04 Jun 2020 18:15
Last Modified:04 Jun 2020 18:15