Quiroga Mellado, Juan Antonio and Rodríguez Ibáñez, Diego and Alonso Fernández, José (2013) Squareness error calibration of a CMM for quality control of ophthalmic lenses. International Journal of Advanced Manufacturing Technology, 68 (1-4). pp. 487-493. ISSN 0268-3768
![]() Preview |
PDF
Creative Commons Attribution. 746kB |
Official URL: http://dx.doi.org/10.1007/s00170-013-4746-y
Abstract
This paper proposes a calibration procedure for the squareness error of small-sized coordinate measuring machines like those used for ophthalmic lenses quality control. The proposed procedure only requires a spherical lens as a reference surface and it only needs to be measured once making this calibration method faster and cheaper than the existing ones.
Item Type: | Article |
---|---|
Additional Information: | © The Author(s) 2013. This article is published with open access at Springerlink.com. |
Uncontrolled Keywords: | CMM, Calibration, Squareness Error, Volumetric Error, Ophthalmic Lenses Quality Control |