Approximate methods to determine the modulation transfer function of a hololens system: a comparative study

Impacto

Downloads

Downloads per month over past year

Varela Vargas, Alberto J. and Calvo Padilla, María Luisa (1995) Approximate methods to determine the modulation transfer function of a hololens system: a comparative study. Optical Engineering, 34 (4). pp. 1116-1121. ISSN 0091-3286

Official URL: http://dx.doi.org/10.1117/12.197083




Abstract

We present a comparative study between two experimental methods to determine the modulation transfer function (MTF) of a hololens system. The two hololenses were previously recorded and tested for filtering pseudocolor. In the first method we used the classical Foucault test. The second, alternative method is based on the digital image processing of a perfect edge under incoherent illumination. From the digitized intensity line profiles we obtain the MTF and cutoff frequency of the optical system according to the reciprocity between line spread function and MTF. Comments are made on the applicability and accuracy of these two methods.


Item Type:Article
Additional Information:

© 2005 COPYRIGHT SPIE--The International Society for Optical Engineering.

Uncontrolled Keywords:Holographic Lenses
Subjects:Sciences > Physics > Optics
ID Code:25754
Deposited On:09 Jun 2014 09:05
Last Modified:09 Jun 2014 09:05

Origin of downloads

Repository Staff Only: item control page