Publication:
Radiation tolerant isolation amplifiers for temperature measurement

Loading...
Thumbnail Image
Full text at PDC
Publication Date
2006-09-29
Authors
Zong, Yi
Agapito Serrano, Juan Andrés
Fernandes, Ana C.
Marques, José G.
Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Science BV
Citations
Google Scholar
Research Projects
Organizational Units
Journal Issue
Abstract
This paper concentrates on the selection of radiation tolerant isolation amplifiers, which are suitable for the signal conditioners for cryogenic system in the Large Hadron Collider (LHC). The evolution and the results of different commercial isolation amplifiers’ parameters under neutron and gamma radiation are presented. In most cases, the tested isolation amplifiers’ input offset voltage, bias currents and output offset voltage hardly changed during the radiation. The \{DC\} gain in input stage was only affected for some isolation amplifiers with a small open loop gain. Transmission coefficient showed decrease for all the tested isolation amplifiers. Also, the \{DC\} output voltage increased and the ripple voltage decreased for all the build-in isolated regulators. In addition, results on 1B41 signal conditioner showed that it was tolerant to 7–8×1012 n/cm2, which was 50\% higher than the expected dose in the LHC.
Description
© 2006 Elsevier.
Unesco subjects
Keywords
Citation
Collections