An analog cell to detect single event transients in voltage references

Impacto

Downloads

Downloads per month over past year



Franco Peláez, Francisco Javier and Palomar Trives, Carlos and González Izquierdo, Jesús and Agapito Serrano, Juan Andrés (2015) An analog cell to detect single event transients in voltage references. Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 770 . 135 - 140. ISSN 0168-9002

[thumbnail of NIMA2015-Franco.pdf]
Preview
PDF
1MB

Official URL: http://www.sciencedirect.com/science/article/pii/S0168900214011231



Abstract

A reliable voltage reference is mandatory in mixed-signal systems. However, this family of components can undergo very long single event transients when operating in radiation environments such as space and nuclear facilities due to the impact of heavy ions. The purpose of the present paper is to demonstrate how a simple cell can be used to detect these transients. The cell was implemented with typical {COTS} components and its behavior was verified by {SPICE} simulations and in a laser facility. Different applications of the cell are explored as well.


Item Type:Article
Additional Information:

© 2015 Elsevier.

Uncontrolled Keywords:Voltage references
Subjects:Sciences > Physics > Electronics
Sciences > Chemistry > Optics
ID Code:28878
Deposited On:03 Mar 2015 09:19
Last Modified:10 Dec 2018 14:57

Origin of downloads

Repository Staff Only: item control page