Repeatability of the Modified Thorington Card Used to Measure Far Heterophoria

Impacto

Downloads

Downloads per month over past year

Cebrián, José Luis and Antona Peñalba, Beatriz and Barrio de Santos, Ana Rosa and González Díaz-Obregón, Enrique and Gutiérrez Hernández, Ángel Luis and Sánchez Pérez, María Isabel (2014) Repeatability of the Modified Thorington Card Used to Measure Far Heterophoria. Optometry and Vision Science, 91 (7). pp. 786-792. ISSN 1040-5488

[thumbnail of 2014_OVS_Repeatability [vers eprint].pdf] PDF
Restringido a Repository staff only

364kB

Official URL: http://dx.doi.org/10.1097/OPX.0000000000000297




Abstract

Purpose. To determine the interexaminer and intraexaminer repeatability of the modified Thorington test (TH) for distance vision in young adults and to compare these results with those observed for the heterophoria tests most commonly used in clinical practice. Agreement among tests was also assessed.

Methods. Distance heterophoria was quantified on two separate occasions by two examiners in 110 subjects aged 18 to 32 years (mean, 19.74 years; SD, 2.5 years) using four different tests: cover test (CT) Von Graefe, Maddox rod, and modified TH. The repeatability of the tests and agreement between them was estimated by the Bland and Altman method whereby the mean difference and the 95% limits of agreement were determined as the coefficient of repeatability (COR) and coefficient of agreement.

Results. The Thorington test showed best interexaminer repeatability (COR = +/- 1.43 Delta), followed closely by CT (COR = +/- 1.65 Delta), whereas best intraexaminer repeatability was observed for CT (COR = +/- 1.28 Delta) followed by TH (COR = +/- 1.51 Delta). Among the different combinations of tests, TH and CT showed best agreement indicated by the lowest coefficient of agreement (+/- 2.23 Delta) and a low mean difference (-0.63 Delta) between measurements.

Conclusions. Good interexaminer and intraexaminer repeatability was observed for both TH and CT, and agreement between the two tests was also good. Given the simple administration of the TH, we recommend its clinical use to quantify distance horizontal heterophoria.


Item Type:Article
Additional Information:

Es la versión postprint. En la web del editor se puede encontrar el artículo "free".

Uncontrolled Keywords:Repeatability; Heterophoria; Thorington; Cover test; Von Graefe; Maddox rod
Subjects:Medical sciences > Optics > Visual perception
ID Code:33304
Deposited On:28 Sep 2015 14:49
Last Modified:28 Sep 2015 15:28