Publication:
Arthroscopic stabilisation of an acute acromioclavicular dislocation grade III in a patient with ectopic insertion of the pectoralis minor: technical considerations

Loading...
Thumbnail Image
Full text at PDC
Publication Date
2016-07
Authors
Minuesa Asensio, Álvaro
Barrio Asensio, María del Carmen
González Gómez, Ignacio
Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Springer-Verlag
Citations
Google Scholar
Research Projects
Organizational Units
Journal Issue
Abstract
The different approaches used in arthroscopic stabilisation of the acromioclavicular joint are well known. However, and despite a great incidence of ectopic pectoralis minor insertion, an alternative choice for the use of arthroscopic portal has not being sufficiently described. Here, we describe a case of acute acromioclavicular dislocation grade III. The arthroscopic stabilisation was achieved using the TightRope (Arthrex, Naples, USA) implant. Through this technique, the approach to the articular portion of the coracoid process can be made intra-articularly or from the subacromial space. We accessed intra-articularly, by opening the rotator interval to reach the coracoid process from the joint cavity. After opening the rotator interval, an ectopic insertion of the pectoralis minor was observed. The choice of approach of the coracoid process from the subacromial space would have complicated the intervention, making it necessary to sever the ectopic tendon to complete the technique, lengthening the surgical time and increasing the chance of complications. For this reason, the use of a standard posterior portal providing intra-articular arthroscopic access through the rotator interval is recommended since the aforementioned anatomical variation is not infrequent. Level of evidence Therapeutic studies—investigating the results of treatment, Level V.
Description
Received: 28 March 2014 / Accepted: 24 November 2014 / Published online: 2 December 2014
Keywords
Citation
1. De Beer JF, Roberts C (2010) Glenoid bone defects—open latarjet with congruent arc modification. Orthop Clin N Am 41(3):407–415 2. Homsi C, Rodrigues MB, Silva JJ, Stump X, Morvan G (2003) Anomalous insertion of the pectoralis minor muscle: ultrasound findings. J Radiol 84(9):1007–1011 3. Le Double AF (1987) Traitè des variations du système musculaire de l'homme et de leur signification au point de vue de l'anthropologie zoologique. In: Libraire C. Rerinwald (ed). Schleicher Frères, Paris pp 252–255 4. Lee SJ, Ha DH, Lee SM (2010) Unusual variation of the rotator interval: insertional abnormality of the pectoralis minor tendon and absence of the coracohumeral ligament. Skelet Radiol 39(12):1205–1209 5. Samuel P, Blanchard JP (1984) Syndrome de la coiffe des rotateurs par anomalie d’insertion du petit pectoral [Rotator cuff syndrome caused by an anomaly of the insertion of the pectoralis minor]. Rev Chir Orthop Reparatrice Appar Mot 70(5):401–404 6. Testut L (1884) Les anomalies musculaires chez l’homme, expliquées par l’anatomie comparée: leur importance en anthropologie.In: G. Masson (ed). Paris, pp 34–44. https://archive.org/details/lesanomaliesmusc00testuoft 7. Tubbs RS, Oakes WJ, Salter EG (2005) Unusual attachment of the pectoralis minor muscle. Clin Anat 18(4):302–304 8. Uzel AP, Bertino R, Caix P, Boileau P (2008) Bilateral variation of the pectoralis minor muscle discovered during practical dissection. Surg Radiol Anat 30(8):679–682 9. Weinstabl R, Hertz H, Firbas W (1986) Zusammenhang des ligamentum coracoglenoidale mit dem musculus pectoralis minor. Acta Anat 125:126–131
Collections