Impacto
Downloads
Downloads per month over past year
Santos Bueso, Enrique and Jiménez Santos, M and Díaz Valle, David and Gegúndez Fernández, José Antonio and Cuiña Sardiña, Ricardo and Benítez del Castillo, José Manuel and García Sánchez, Julián (2016) Cuerpo extraño enclavado en iris después de cirugía de catarata. Archivos de la Sociedad Española de Oftalmología, 91 (3). pp. 134-137. ISSN 0365-6691
![]() |
PDF
Restringido a Repository staff only 220kB |
Official URL: http://dx.doi.org/10.1016/j.oftal.2015.11.004
Abstract
Caso clínico: mujer de 75 años intervenida de catarata en ojo izquierdo, que presentaba a las 24h una agudeza visual de 0,8. En la biomicroscopia destacaba un cuerpo extraño anclado al iris en sector nasal coincidente con la incisión principal de la facoemulsificación, que fue retirado en un segundo acto quirúrgico. Fue analizado e informado como estructura inerte de naturaleza plástica.
Discusión: planteamos el posible origen de la presencia del resto plástico en el postoperatorio de la cirugía de la catarata. En este caso su naturaleza inerte no desencadenó mayor inflamación intraocular. Además, la estructura rígida favoreció su anclaje al iris evitando otras complicaciones. Deben extremarse las medidas preventivas en la cirugía de la catarata revisando incluso los instrumentos y accesorios al terminar la cirugía.
Resumen (otros idiomas)
Case report: a 75-year old woman who had had cataract surgery in her left eye and showed a visual acuity of 0.8 twenty-four hours post-surgery. Biomicroscopy revealed a foreign body attached to the iris in the nasal sector that coincided with the main incision of the phacoemulsification, which was then removed in a second surgical procedure. It was analysed and described as an inert structure made of plastic. Discussion: The possible origin of the presence of a fragment of plastic in the postoperative period following cataract surgery is established. In this case, its inert nature did not cause any further intraocular inflammation. Its rigid structure also favoured its attachment to the iris, thus avoiding any other complications. There must be greater preventative measures during cataract surgery, including checking the instruments and accessories before and after the surgical procedure.
Item Type: | Article |
---|---|
Additional Information: | Recibido 29 noviembre 2014, Aceptado 03 noviembre 2015. |
Uncontrolled Keywords: | Cuerpo extraño, Iris, Cirugía de catarata, Facoemulsificación, Plástico |
Palabras clave (otros idiomas): | Foreign body, Iris, Cataract surgery, Phacoemulsification, Plastic |
Subjects: | Medical sciences > Medicine > Surgery Medical sciences > Medicine > Ophtalmology |
ID Code: | 42536 |
Deposited On: | 17 May 2017 12:38 |
Last Modified: | 17 May 2017 12:38 |
Origin of downloads
Repository Staff Only: item control page