¡Nos trasladamos! E-Prints cerrará el 7 de junio.

En las próximas semanas vamos a migrar nuestro repositorio a una nueva plataforma con muchas funcionalidades nuevas. En esta migración las fechas clave del proceso son las siguientes:

Es muy importante que cualquier depósito se realice en E-Prints Complutense antes del 7 de junio. En caso de urgencia para realizar un depósito, se puede comunicar a docta@ucm.es.

Electrochemical immunosensor for simultaneous determination of interleukin-1 beta and tumor necrosis factor alpha in serum and saliva using dual screen printed electrodes modified with functionalized double–walled carbon nanotubes

Impacto

Downloads

Downloads per month over past year



Sánchez Tirado, Esther and Salvo, Coral and González Cortés, Araceli and Yáñez Sedeño, Paloma and Langa, Fernando and Pingarrón Carrazón, José Manuel (2016) Electrochemical immunosensor for simultaneous determination of interleukin-1 beta and tumor necrosis factor alpha in serum and saliva using dual screen printed electrodes modified with functionalized double–walled carbon nanotubes. Analytica Chimica Acta, 959 . pp. 66-73. ISSN 0003-2670

[thumbnail of Paper dual saliva revised (clean) (1)Paloma.pdf]
Preview
PDF
765kB

Official URL: https://www.sciencedirect.com/science/article/pii/S0003267016315094



Abstract

Dual screen-printed carbon electrodes modified with 4-carboxyphenyl-functionalized double-walled carbon nanotubes (HOOC-Phe-DWCNTs/SPCEs) have been used as scaffolds for the preparation of electrochemical immunosensors for the simultaneous determination of the cytokines Interleukin-1b (IL-1b) and factor necrosis tumor a (TNF-a). IL-1b. Capture antibodies were immobilized onto HOOC-Phe DWCNTs/SPCEs in an oriented form making using the commercial polymeric coating Mix&Go™. Sandwich type immunoassays with amperometric signal amplification through the use of poly-HRPstreptavidin conjugates and H2O2 as HRP substrate and hydroquinone as redox mediator were implemented. Upon optimization of the experimental variables affecting the immunosensor performance, the dual immunosensor allows ranges of linearity extending between 0.5 and 100 pg/mL and from 1 to 200 pg/mL for IL-1b and TNF-a, respectively, these ranges being adequate for the determination of the cytokines in clinical samples. The achieved limits of detection were 0.38 pg/mL (IL-1b) and 0.85 pg/mL (TNF-a). In addition, the dual immunosensor exhibits excellent reproducibility of the measurements, storage stability of the anti-IL-Phe-DWCNTs/SPCE and anti-TNF-Phe-DWCNTs/SPCE conjugates, and selectivity as well as negligible cross-talking. The dual immunosensor was applied to the simultaneous determination of IL-1b and TNF-a in human serum spiked at clinically relevant concentration levels and in real saliva samples.


Item Type:Article
Uncontrolled Keywords:interleukin-1 beta; tumor necrosis factor-alpha; electrochemical immunosensor; multiplex; double-walled carbon nanotubes; saliva.
Subjects:Sciences > Chemistry > Analytic chemistry
ID Code:44483
Deposited On:13 Mar 2018 09:31
Last Modified:05 Aug 2019 08:54

Origin of downloads

Repository Staff Only: item control page