Publication:
Efectos de distintas soluciones irrigadoras en la resistencia a la fatiga cíclica de instrumentos WaveOneGoldGlider y ProGlider

Loading...
Thumbnail Image
Official URL
Full text at PDC
Publication Date
2019
Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
Citations
Google Scholar
Research Projects
Organizational Units
Journal Issue
Abstract
Description
Keywords
Citation
1. Adams N, Tomson PL. Access cavity preparation. Br Dent J. 2014;216(6):333-9. 2. Wang FE, Buehler WJ, Pickart SJ. Crystal Structure and a Unique ``Martensitic’’ Transition of TiNi. J Appl Phys. 1965;36(10):3232-9. 3. Serene TP, Adams JD, Saxena A. Nickel-titanium instruments: applications in endodontics. 1995. 4. Shen Y, Zhou H, Zheng Y, Peng B, Haapasalo M. Current Challenges and Concepts of the Thermomechanical Treatment of Nickel-Titanium Instruments. J Endod. 2013;39(2):163-72. 5. Shaw JA, Churchill CB, Iadicola MA. TIPS AND TRICKS FOR CHARACTERIZING SHAPE MEMORY ALLOY WIRE: PART 1-DIFFERENTIAL SCANNING CALORIMETRY AND BASIC PHENOMENA. Exp Tech. 2008;32(5):55-62. 6. Brantley W, Svec T, Iijima M, Powers J, Grentzer T. Differential Scanning Calorimetric Studies of Nickel Titanium Rotary Endodontic Instruments. J Endod. 2002;28(8):567-72. 7. Thompson SA. An overview of nickel-titanium alloys used in dentistry. Int Endod J. 2000;33(4):297-310. 8. Hilfer PB, Bergeron BE, Mayerchak MJ, Roberts HW, Jeansonne BG. Multiple Autoclave Cycle Effects on Cyclic Fatigue of Nickel-Titanium Rotary Files Produced by New Manufacturing Methods. J Endod. 2011;37(1):72-4. 9. Shen Y, Qian W, Abtin H, Gao Y, Haapasalo M. Effect of Environment on Fatigue Failure of Controlled Memory Wire Nickel-Titanium Rotary Instruments. J Endod. 38(3):376-80. 10. Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod. 1988;14(7):346-51. 11. Glossen CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments. J Endod. 1995;21(3):146-51. 12. Short JA, Morgan LA, Baumgartner JC. A comparison of canal centering ability of four instrumentation techniques. J Endod. 1997;23(8):503-7. 13. Zhao D, Shen Y, Peng B, Haapasalo M. Micro–Computed Tomography Evaluation of the Preparation of Mesiobuccal Root Canals in Maxillary First Molars with Hyflex CM, Twisted Files, and K3 Instruments. J Endod. 2013;39(3):385-8. 14. Gambarini G, Gerosa R, De Luca M, Garala M, Testarelli L. Mechanical properties of a new and improved nickel-titanium alloy for endodontic use: an evaluation of file flexibility. Oral Surg Oral Med Oral Pathol Oral Radiol Endodontology.105(6):798-800. 15. Davis JR, ASM International, Edit. Nickel, cobalt, and their alloys. Materials Park, OH: ASM International; 2000. 442 p. (ASM specialty handbook). 16. Shen Y, Qian W, Abtin H, Gao Y, Haapasalo M. Fatigue Testing of Controlled Memory Wire Nickel-Titanium Rotary Instruments. J Endod. 2011;37(7):997-1001. 17. Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D. Evaluation of the Impact of Raw Materials on the Fatigue and Mechanical Properties of ProFile Vortex Rotary Instruments. J Endod. 2012;38(3):398-401. 18. Zhou H, Shen Y, Zheng W, Li L, Zheng Y, Haapasalo M. Mechanical Properties of Controlled Memory and Superelastic Nickel-Titanium Wires Used in the Manufacture of Rotary Endodontic Instruments. J Endod. 2012;38(11):1535-40. 19. Gutmann JL, Gao Y. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review: Treatment of NiTi instruments. Int Endod J. 2012;45(2):113-28. 20. Hayashi Y, Yoneyama T, Yahata Y, Miyai K, Doi H, Hanawa T, et al. Phase transformation behaviour and bending properties of hybrid nickel?titanium rotary endodontic instruments. Int Endod J. 2007;40(4):247-53. 21. Yahata Y, Yoneyama T, Hayashi Y, Ebihara A, Doi H, Hanawa T, et al. Effect of heat treatment on transformation temperatures and bending properties of nickeltitanium endodontic instruments. Int Endod J. 2009;42(7):621-6. 22. Alapati SB, Brantley WA, Iijima M, Clark WAT, Kovarik L, Buie C, et al. Metallurgical Characterization of a New Nickel-Titanium Wire for Rotary Endodontic Instruments. J Endod. 2009;35(11):1589-93. 23. Kuhn G, Jordan L. Fatigue and Mechanical Properties of Nickel-Titanium Endodontic Instruments. J Endod. 2002;28(10):716-20. 24. Zinelis S, Darabara M, Takase T, Ogane K, Papadimitriou GD. The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue. Oral Surg Oral Med Oral Pathol Oral Radiol Endodontology. 2007;103(6):843-7. 25. Pereira ESJ, Gomes RO, Leroy AMF, Singh R, Peters OA, Bahia MGA, et al. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments. Dent Mater. 2013;29(12):e318-24. 26. Ye J, Gao Y. Metallurgical Characterization of M-Wire Nickel-Titanium Shape Memory Alloy Used for Endodontic Rotary Instruments during Low-cycle Fatigue. J Endod. 2012;38(1):105-7. 27. Arias A, Perez-Higueras JJ, de la Macorra JC. Influence of clinical usage of GT and GTX files on cyclic fatigue resistance. Int Endod J. 2014;47(3):257-63. 28. Pérez-Higueras JJ, Arias A, de la Macorra JC, Peters OA. Differences in Cyclic Fatigue Resistance between ProTaper Next and ProTaper Universal Instruments at Different Levels. J Endod. 2014;40(9):1477-81. 29. TFTM Twisted Files [Internet]. Kerr Dental. 2015 [citado 13 de mayo de 2019]. Disponible en: https://www.kerrdental.com/kerr-endodontics/tf-twistedfiles-shape 30. Pirani C, Cirulli PP, Chersoni S, Micele L, Ruggeri O, Prati C. Cyclic Fatigue Testing and Metallographic Analysis of Nickel-Titanium Rotary Instruments. J Endod. 2011;37(7):1013-6. 31. HyFlex Rotary Files [Internet]. [citado 13 de mayo de 2019]. Disponible en: https://www.coltene.com/products/endodontics/rotary-files/hyflex-rotary-files/ 32. Plotino G, Grande NM, Cotti E, Testarelli L, Gambarini G. Blue Treatment Enhances Cyclic Fatigue Resistance of Vortex Nickel-Titanium Rotary Files. J Endod. 2014;40(9):1451-3. 33. Pereira ÉSJ, Viana ACD, Buono VTL, Peters OA, Azevedo Bahia MG de. Behavior of Nickel-Titanium Instruments Manufactured with Different Thermal Treatments. J Endod. 2015;41(1):67-71. 34. Plotino G, Grande NM, Mercadé Bellido M, Testarelli L, Gambarini G. Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files. J Endod. 2017;43(2):200-2. 35. Elnaghy AM, Elsaka SE. Mechanical properties of ProTaper Gold nickeltitanium rotary instruments. Int Endod J. 2016;49(11):1073-8. 36. Shen Y, Zhou H, Zheng Y, Campbell L, Peng B, Haapasalo M. Metallurgical Characterization of Controlled Memory Wire Nickel-Titanium Rotary Instruments. J Endod. 2011;37(11):1566-71. 37. Gündoğar M, Özyürek T. Cyclic Fatigue Resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue Nickel-titanium Instruments. J Endod. 2017;43(7):1192-6. 38. WAVEONE GOLD | Product Categories | Dentsply Maillefer [Internet]. [citado 9 de mayo de 2019]. Disponible en: http://www.dentsplymaillefer.com/product-category/glide-pathshaping/waveone-gold 39. Yared G. Canal preparation using only one Ni-Ti rotary instrument: preliminary observations. Int Endod J. 2008;41(4):339-44. 40. Bird DC, Chambers D, Peters OA. Usage Parameters of Nickel-Titanium Rotary Instruments: A Survey of Endodontists in the United States. J Endod. 2009;35(9):1193-7. 41. Roane J, Sabala C, Duncansonjr M. The “balanced force” concept for instrumentation of curved canals. J Endod. 1985;11(5):203-11. 42. Grande NM, Ahmed HMA, Cohen S, Bukiet F, Plotino G. Current Assessment of Reciprocation in Endodontic Preparation: A Comprehensive Review—Part I: Historic Perspectives and Current Applications. J Endod. 2015;41(11):1778-83. 43. Karataş E, Gündüz HA, Kırıcı DÖ, Arslan H, Topçu MÇ, Yeter KY. Dentinal Crack Formation during Root Canal Preparations by the Twisted File Adaptive, ProTaper Next, ProTaper Universal, and WaveOne Instruments. J Endod. 2015;41(2):261-4. 44. Sattapan B, Nervo G, Palamara J, Messer H. Defects in Rotary NickelTitanium Files After Clinical Use. J Endod. 2000;26(3):161-5. 45. Arias A, Singh R, Peters OA. Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation. Odontology. 2016;104(2):192-8. 46. Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod. 1997;23(2):77-85. 47. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32(2):271-5. 48. Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments. J Endod. 2009;35(11):1469-76. 49. Nahmias Y, Cassim I. “Own the Canal”–The Importance of a Reproducible Glide Path. 2013;71. 50. Berman LH, Hargreaves KM, Cohen SR. Cohen’s Pathways of the Pulp Expert Consult. [Internet]. London: Elsevier Health Sciences; 2010 [citado 27 de diciembre de 2018]. 290–357 p. Disponible en: http://public.eblib.com/choice/publicfullrecord.aspx?p=1430210 51. Berutti E, Alovisi M, Pastorelli MA, Chiandussi G, Scotti N, Pasqualini D. Energy Consumption of ProTaper Next X1 after Glide Path with PathFiles and ProGlider. J Endod. 2014;40(12):2015-8. 52. Patino P, Biedma B, Liebana C, Cantatore G, Bahillo J. The Influence of a Manual Glide Path on the Separation Rate of NiTi Rotary Instruments. J Endod. 2005;31(2):114-6. 53. Elnaghy AM, Elsaka SE. Evaluation of Root Canal Transportation, Centering Ratio, and Remaining Dentin Thickness Associated with ProTaper Next Instruments with and without Glide Path. J Endod. 2014;40(12):2053-6. 54. Ajuz NCC, Armada L, Gonçalves LS, Debelian G, Siqueira JF. Glide Path Preparation in S-shaped Canals with Rotary Pathfinding Nickel-Titanium Instruments. J Endod. 2013;39(4):534-7. 55. D’Amario M, Baldi M, Petricca R, De Angelis F, El Abed R, D’Arcangelo C. Evaluation of a New Nickel-Titanium System to Create the Glide Path in Root Canal Preparation of Curved Canals. J Endod. 2013;39(12):1581-4. 56. Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G, et al. Use of Nickel-Titanium Rotary PathFile to Create the Glide Path: Comparison With Manual Preflaring in Simulated Root Canals. J Endod. 2009;35(3):408-12. 57. Chen J, Messer H. A Comparison of Stainless Steel Hand and Rotary NickelTitanium Instrumentation Using a Silicone Impression Technique. Aust Dent J. 2002;47(1):12-20. 58. Peters O. Current Challenges and Concepts in the Preparation of Root Canal Systems: A Review. J Endod. 2004;30(8):559-67. 59. Schafer E, Schulzbongert U, Tulus G. Comparison of Hand Stainless Steel and Nickel Titanium Rotary Instrumentation: A Clinical Study. J Endod. 2004;30(6):432-5. 60. PROGLIDER | Product Categories | Dentsply Maillefer [Internet]. [citado 14 de mayo de 2019]. Disponible en: http://www.dentsplymaillefer.com/productcategory/glide-path-shaping/glide-path/proglider 61. Santos CB, Carvalho MS, Perez R, Vieira VTL, Antunes HS, Cavalcante DM, et al. Torsional fatigue resistance of R-Pilot and WaveOne Gold Glider NiTi glidepath reciprocating systems. Int Endod J [Internet]. 2018 [citado 27 de diciembre de 2018]; Disponible en: http://doi.wiley.com/10.1111/iej.13068 62. WAVEONE GOLD GLIDER | Product Categories | Dentsply Maillefer [Internet]. [citado 14 de mayo de 2019]. Disponible en: http://www.dentsplymaillefer.com/product-category/glide-path-shaping/glidepath/waveone-gold-glider 63. Zehnder M. Root Canal Irrigants. J Endod. 2006;32(5):389-98. 64. Bonaccorso A, Tripi TR, Rondelli G, Condorelli GG, Cantatore G, Schäfer E. Pitting Corrosion Resistance of Nickel–Titanium Rotary Instruments with Different Surface Treatments in Seventeen Percent Ethylenediaminetetraacetic Acid and Sodium Chloride Solutions. J Endod. 2008;34(2):208-11. 65. Pérez-Heredia M, Ferrer-Luque CM, González-Rodríguez MP. The Effectiveness of Different Acid Irrigating Solutions in Root Canal Cleaning After Hand and Rotary Instrumentation. J Endod. 32(10):993-7. 66. Yamada RS, Armas A, Goldman M, Lin PS. A scanning electron microscopic comparison of a high volume final flush with several irrigating solutions: Part 3. J Endod. 1983;9(4):137-42. 67. Sarkar NK, Redmond W, Schwaninger B, Goldberg AJ. The chloride corrosion behaviour of four orthodontic wires. J Oral Rehabil. 1983;10(2):121-8. 68. Cheung GSP, Darvell BW. Low-cycle fatigue of rotary NiTi endodontic instruments in hypochlorite solution. Dent Mater. 2008;24(6):753-9. 69. Krishnan U, Saji S, Clarkson R, Lalloo R, Moule AJ. Free Active Chlorine in Sodium Hypochlorite Solutions Admixed with Octenidine, SmearOFF, Chlorhexidine, and EDTA. J Endod. 2017;43(8):1354-9. 70. Zehnder M, Schmidlin P, Sener B, Waltimo T. Chelation in root canal therapy reconsidered. J Endod. 2005;31(11):817-20. 71. Tartari T, Guimarães BM, Amoras LS, Duarte MAH, Silva e Souza PAR, Bramante CM. Etidronate causes minimal changes in the ability of sodium hypochlorite to dissolve organic matter. Int Endod J. 2015;48(4):399-404. 72. Tartari T, Bachmann L, Zancan RF, Vivan RR, Duarte MAH, Bramante CM. Analysis of the effects of several decalcifying agents alone and in combination with sodium hypochlorite on the chemical composition of dentine. Int Endod J. 2018;51:e42-54. 73. Lottanti S, Gautschi H, Sener B, Zehnder M. Effects of ethylenediaminetetraacetic, etidronic and peracetic acid irrigation on human root dentine and the smear layer. Int Endod J. 2009;42(4):335-43. 74. Vorster M, van der Vyver PJ, Paleker F. Influence of Glide Path Preparation on the Canal Shaping Times of WaveOne Gold in Curved Mandibular Molar Canals. J Endod. 2018;44(5):853-5. 75. Arias A, Macorra JC, Govindjee S, Peters OA. Correlation between Temperature-dependent Fatigue Resistance and Differential Scanning Calorimetry Analysis for 2 Contemporary Rotary Instruments. J Endod. 2018;44(4):630-4. 76. Grande NM, Plotino G, Silla E, Pedullà E, DeDeus G, Gambarini G, et al. Environmental Temperature Drastically Affects Flexural Fatigue Resistance of Nickel-titanium Rotary Files. J Endod. 2017;43(7):1157-60. 77. Invention: Endodontic Access Kit | Advanced Endodontics [Internet]. [citado 22 de mayo de 2019]. Disponible en: https://www.endoruddle.com/GoldGlider 78. ProGlider File | Advanced Endodontics [Internet]. [citado 6 de junio de 2019]. Disponible en: https://www.endoruddle.com/ProGlider 79. Arias A, Perez-Higueras JJ, de la Macorra JC. Differences in Cyclic Fatigue Resistance at Apical and Coronal Levels of Reciproc and WaveOne New Files. J Endod. 2012;38(9):1244-8. 80. Lu C, Danzer R, Fischer FD. Fracture statistics of brittle materials: Weibull or normal distribution. Phys Rev E [Internet]. 13 de junio de 2002 [citado 3 de enero de 2019];65(6). Disponible en: https://link.aps.org/doi/10.1103/PhysRevE.65.067102 81. Abernethy RB. The new Weibull handbook: reliability & statistical analysis for predicting life, safety, risk, support costs, failures, and forecasting warranty claims, substantiation and accelerated testing, using Weibull, Log normal, CrowAMSAA, Probit, and Kaplan-Meier models. North Palm Beach, Fla.: R.B. Abernethy; 2008. 82. Lopes HP, Elias CN, Vieira MVB, Siqueira JF, Mangelli M, Lopes WSP, et al. Fatigue Life of Reciproc and Mtwo Instruments Subjected to Static and Dynamic Tests. J Endod. 2013;39(5):693-6. 83. Larsen CM, Watanabe I, Glickman GN, He J. Cyclic Fatigue Analysis of a New Generation of Nickel Titanium Rotary Instruments. J Endod. 2009;35(3):401-3. 84. Lambrighs K, Wevers M, Verlinden B, Verpoest I. A fracture mechanics approach to fatigue of heavily drawn steel wires. Procedia Eng. 2011;10:3259-66. 85. Sun CQ. Thermo-mechanical behavior of low-dimensional systems: The local bond average approach. Prog Mater Sci. 2009;54(2):179-307. 86. Quinn JB, Quinn GD. A practical and systematic review of Weibull statistics for reporting strengths of dental materials. Dent Mater. 2010;26(2):135-47. 87. Ferrari M, Goracci C, Sadek F, Eduardo P, Cardoso C. Microtensile bond strength tests: scanning electron microscopy evaluation of sample integrity before testing. Eur J Oral Sci. 2002;110(5):385-91. 88. Burrow MF, Thomas D, Swain MV, Tyas MJ. Analysis of tensile bond strengths using Weibull statistics. Biomaterials. 2004;25(20):5031-5. 89. Versluis A, Kim H-C, Lee W, Kim B-M, Lee C-J. Flexural Stiffness and Stresses in Nickel-Titanium Rotary Files for Various Pitch and Cross-sectional Geometries. J Endod. 2012;38(10):1399-403. 90. Keskin C, Inan U, Demiral M, Keleş A. Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments. J Endod. 2017;43(8):1360-3. 91. Hieawy A, Haapasalo M, Zhou H, Wang Z, Shen Y. Phase Transformation Behavior and Resistance to Bending and Cyclic Fatigue of ProTaper Gold and ProTaper Universal Instruments. J Endod. 2015;41(7):1134-8. 92. Wright PP, Kahler B, Walsh LJ. Alkaline Sodium Hypochlorite Irrigant and Its Chemical Interactions. Materials. 2017;10(10):1147. 93. Alfawaz H, Alqedairi A, Alsharekh H, Almuzaini E, Alzahrani S, Jamleh A. Effects of Sodium Hypochlorite Concentration and Temperature on the Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Rotary Instruments. J Endod. 2018;44(10):1563-6. 94. Silva e Souza PAR, das Dores RSE, Tartari T, Pinheiro TPS, Tuji FM, Silva e Souza MH. Effects of sodium hypochlorite associated with EDTA and etidronate on apical root transportation. Int Endod J. 2014;47(1):20-5. 95. Ballal NV, Gandhi P, Shenoy PA, Shenoy Belle V, Bhat V, Rechenberg D ‐K., et al. Safety assessment of an etidronate in a sodium hypochlorite solution: randomized double‐blind trial. Int Endod J. 2019;iej.13129. 96. Erik CE, Özyürek T. Effects of etidronate, NaOCl, EDTA irrigation solutions and their combinations on cyclic fatigue resistance of nickel–titanium single-file rotary and reciprocating instruments at body temperature. Odontology. 2019;107(2):190-5.