¡Nos trasladamos! E-Prints cerrará el 7 de junio.

En las próximas semanas vamos a migrar nuestro repositorio a una nueva plataforma con muchas funcionalidades nuevas. En esta migración las fechas clave del proceso son las siguientes:

Es muy importante que cualquier depósito se realice en E-Prints Complutense antes del 7 de junio. En caso de urgencia para realizar un depósito, se puede comunicar a docta@ucm.es.

Is soft toric contact lenses fitting a feasible option to improve optical quality and visual performance in corneal ectasia?

Impacto

Downloads

Downloads per month over past year

Carballo Álvarez, Jesús and Marí Ribas, Marina and Martín Gonzalez, Abel and Batres Valderas, Laura (2021) Is soft toric contact lenses fitting a feasible option to improve optical quality and visual performance in corneal ectasia? Contact Lens and Anterior Eye . 6 p.. ISSN 1367-0484 (In Press)

[thumbnail of Postprint] PDF (Postprint)
Creative Commons Attribution Non-commercial No Derivatives.

464kB

Official URL: https://doi.org/10.1016/j.clae.2021.03.001




Abstract

Objectives: To assess the feasibility of fitting soft toric contact lenses (STCL) in corneal ectasias and their impact on optical quality and visual performance.
Methods: A total of 22 eyes were fitted with a molded STCL: 11 eyes/9 subjects with corneal ectasia and 11 healthy eyes/11 subjects. Wavefront aberrations were analyzed using a Hartmann-Shack aberrometer. Visual performance was measured under photopic (85 cd/m 2) and mesopic (≤3 cd/m 2) conditions. High-(96 %) and low- (10 %) contrast VA (HCVA and LCVA respectively) were assessed using the ETDRS charts and contrast sensitivity (CS) using the Pelli-Robson chart.
Results: After STCL fitting in the ectatic corneas, oblique astigmatism increased 0.15±0.17 μm and 0.34 ± 0.36 μm for 3 mm- and mesopic pupil diameters, respectively.
Mean defocus decreased 1.41 ± 0.36 μm and 2.17 ± 0.85 μm for the same pupil diameters. More positive values of vertical coma were found with a change of 0.05 ± 0.06 μm and 0.12 ± 0.10 μm for 3 mm and mesopic pupil diameters, respectively. Comparing changes between both groups, with a 3 mm pupil aperture, statistically significant differences (p < 0.05) were detected in oblique astigmatism, defocus, vertical secondary trefoil and horizontal secondary coma. In the group with corneal ectasia, photopic HCVA and LCVA improved 0.09 ± 0.11 logMAR and 0.12 ± 0.15 logMAR respectively. In mesopic conditions, HCVA, LCVA and CS improved 0.11 ± 0.12 logMAR, 0.18 ± 0.15 logMAR and 0.11 ± 0.07 log. units, respectively.
Conclusions: The analyzed molded soft toric contact lens is a feasible option for good vision in corneal ectasia with moderate irregularity and negative vertical coma.


Item Type:Article
Additional Information:

Received 21 October 2020, Revised 17 February 2021, Accepted 7 March 2021, Available online 11 March 2021.

Uncontrolled Keywords:Ectasia ; Soft toric contact lens ; Optical quality ; Visual performance
Subjects:Medical sciences > Optics > Contact lenses
Medical sciences > Optics > Optometry
Medical sciences > Optics > Optical materials
ID Code:64635
Deposited On:08 Apr 2021 10:39
Last Modified:11 Mar 2022 23:00

Origin of downloads

Repository Staff Only: item control page