Fracture resistance of cantilevered full-arch implant-supported hybrid prostheses with carbon fiber frameworks after thermal cycling

Impacto

Downloads

Downloads per month over past year

Haroyan Darbinyan, Evelina and Romeo Rubio, Marta and Río Highsmith, Jaime del and Lynch, Christopher D. and Castillo Oyagüe, Raquel (2022) Fracture resistance of cantilevered full-arch implant-supported hybrid prostheses with carbon fiber frameworks after thermal cycling. Journal of dentistry, 116 . p. 103902. ISSN 0300-5712

[thumbnail of 1-s2.0-S0300571221003249-main.pdf]
Preview
PDF
Creative Commons Attribution Non-commercial No Derivatives.

13MB

Official URL: https://doi.org/10.1016/j.jdent.2021.103902



Abstract

Objectives: This in vitro study aimed to find the best combination of mesostructure and veneering materials for full-arch implant-supported hybrid prostheses (HPs) in terms of the fracture resistance (FR) of their cantilevers.

Methods: Three groups (n = 5 each) of maxillary HPs were fabricated: Group-1 (CC-A, control): Co-Cr frameworks coated with acrylic resin; Group-2 (CF-A): carbon fiber veneered with acrylic resin; and Group-3 (CF-R): carbon fiber coated with composite resin. All specimens were submitted to 5,000 thermal cycles (5 ◦C – 55 ◦C, dwell time: 30 s), and subjected to a single cantilever bending test in a universal testing machine (crosshead speed: 0.5 mm/min) until failure. The fracture pattern was assessed using stereo microscope and SEM. The one-way ANOVA and Bonferroni tests were run (α= 0.05).

Results: The FR yielded significant differences among the three groups (p< 0.001). CC-A samples reached the highest FR values (p ≤ 0.001), whereas both CF-A and CF-R HPs exhibited the comparably (p = 0.107) lowest FR. CC-A specimens failed cohesively (100%): mostly without chipping (80%). CF-A mesostructures were always broken at the connections of the distal implants. CF-R prostheses often failed adhesively (80%).

Conclusions: The HPs made of Co-Cr veneered with acrylic demonstrated the best mechanical behavior, being the only group whose 13-mm long cantilevers exceeded the clinically acceptable FR of 900 N. The HPs constructed with carbon fiber frameworks showed, additionally, more unfavorable fracture patterns. Clinical significance: For HPs with cantilevers up to 13 mm, Co-Cr mesostructures coated with acrylic may represent the optimum combination of materials.


Item Type:Article
Additional Information:

CRUE-CSIC (Acuerdos Transformativos 2021)

Uncontrolled Keywords:Full-arch implant-supported hybrid prostheses; Cantilever; Prosthetic frameworks; Carbon fiber; Cobalt-chromium; Resin veneering
Subjects:Medical sciences > Dentistry
Medical sciences > Dentistry > Dental implants
ID Code:70247
Deposited On:09 Feb 2022 12:42
Last Modified:18 Feb 2022 10:49

Origin of downloads

Repository Staff Only: item control page